| ... | Cast-in Collar Fire Rated Floor Waste Kits

Cast-in Collar Fire Rated Floor Waste Kits

cast in fire floor waste kit fire cell rated concrete slab passive fire PFP protection
cast in fire floor waste kit fire cell rated concrete slab passive fire PFP protection

Cast-in Collar Fire Rated Floor Waste Kits

Allproof Cast-In Fire Rated Floor Waste Kits provide complete passive fire protection for floor waste penetrations in on-site poured concrete slabs. The integrated cast-in fire collar and adjustable spigot puddle flange simplify installation and eliminate the need for retrofit solutions. Tested with riser junctions and gully traps, these kits deliver a fully compliant fire-rated system ideal for medium- and high-density builds such as apartments and multi-storey developments.

Features:

    • Cast-in fire collar for on-site poured slabs
    • Includes Cyclone or Tilt A Grate puddle flange
    • Adjustable spigots for faster installation
    • Fire tested with riser junctions and gully traps
    • Suitable for multi-system convergence (e.g., shower and floor waste)
    • Ideal for medium- and high-density developments

Branz Appraised Icon  Allproof specification masterspec

 Subscribe for Product Updates

Full passive fire plumbing technical manual.

Fire Rated Floor Wastes

wdt_ID Code Description .pdf File CAD File
9 CYC100 FR 100mm Cyclone Fire Rated
10 TG100 FR 100mm Tilt A Grate Fire Rated

Cast-In Fire Collars


Low Cast-In Collars

Installation Instructions:

    1. Nail to formwork in correct location.
    2. Pour concrete floor.
    3. Remove formwork ensuring galvanised steel ring is exposed.
    4. Cut plastic collar to desired height.
    5. Install pipework and fire rated floor waste kit.

Installation Details